Description
Each of the manufacturers of laser gas welding systems has their own specifications for the gas transfer system. The systems presented here generally meet or exceed the requirements of virtually all of the manufacturers. The manual, semi-automatic, and fully automatic systems have worked very successfully in many laser applications and contain all of the basic components required to protect the laser and maintain gas purity and flow. If for any reason, one of these systems does not meet your requirements contact us to discuss a custom system that is correct for your laser.
Features
- All high purity construction.
- Purge assemblies installed on each pigtail to ensure cylinderto- cylinder purity on change-outs. (Cylinder connections with integral check valves in place of purge assemblies are available as an option.)
- Built-in safety relief valve prevents laser over pressurization.
- Built-in 2 micron filter eliminate particulate contamination of the laser.
- Pigtails are 3’ stainless steel flexible hose with stainless steel inner core to ensure contamination-free gas transfer and eliminate helium diffusion leakage.
- Convenient wall mounting bracket provided.
- High purity brass pressure regulator(s) with stainless steel diaphragms included.
- Designed to provide continuous gas flow to laser during cylinder change-outs.
Specifications And Materials of Construction
Max. Inlet Pressure |
3000 psig |
Inlet Pressure Gauges |
0-4000 psig |
Outlet Pressure Range |
0-100 psig |
Outlet Pressure Gauge |
0-200 psig |
Safety Relief Valve |
set @ 100psig |
Outlet Line Filter |
2 micron sintered stainless steel |
Body |
brass |
Diaphragms |
stainless steel |
Seats and Seals |
Teflon, Tefzel, or Kel-F |
Pigtails |
316 stainless steel with brass cylinder connections |
Operating Temp. |
-40 to 140°F |
How To Order
Model* | Changeover Control |
917-LASER-CGA-4610 |
manual system with purge assemblies on pigtails |
917-LASER-CV-CGA |
manual system with integral check valves, but no purge assemblies |
914-LASER-CGA-4610 |
914 semi-automatic changeover manifold (see page 42) with purge assemblies |
914-LASER-CV-CGA |
914 semi-automatic changeover manifold (see page 42) with integral check valves, but no purge assemblies |
918TS-LASER-CGA-4610 |
918TS Auto-Logic II changeover manifold (see page 40) with purge assemblies |
918TS-LASER-CV-CGA |
918TS Auto-Logic II changeover manifold (see page 40) with integral check valves, but no purge assemblies |
918TS-LASER-CGA-4610 |
919TS Ultra-Logic changeover manifold (see page 38) with purge assemblies |
918TS-LASER-CV-CGA |
919TS Ultra-Logic changeover manifold (see page 38) with integral check valves, but no purge assemblies |
* Specify CGA connection when ordering. |
Options** |
917PS-XXX |
pressure switch alarm assembly (XXX – specify pressure setting desired 300 psig recommended). |
912-AVA |
audio/visual alarm module for 917 gas transfer system (see page 40). |
914-3B |
pressure switch alarm assembly (XXX – specify pressure setting desired 300 psig recommended). |
914-AVA |
audio/visual alarm module for 914 changeover manifold (see page 40). |
** 918TS and 919TS changeover manifolds have a built-in alarm system as standard. |